Sign In | Join Free | My entremaqueros.com
China Hongqi Automatic Control (Jiangsu) Co., Ltd. logo
Hongqi Automatic Control (Jiangsu) Co., Ltd.
Hongqi Automatic Control (Jiangsu) Co., Ltd.
Verified Supplier

1 Years

Home > Electromagnetic Flow Meter >

Split Type Electromagnetic Flow Meter

Hongqi Automatic Control (Jiangsu) Co., Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now

Split Type Electromagnetic Flow Meter

  • 1
  • 2

Brand Name : JSHQ

Model Number : HQ-LDE

Certification : CE, MC, CQC, SIL, ISO

Place of Origin : Jiangsu, China

Contact Now

Split Type Electromagnetic Flow Meter

Split Type Electromagnetic Flow Meter

Split Type Electromagnetic Flow Meter

Split Type Electromagnetic Flow Meter

1. Product Brief Introduction:

HQ-LDE intelligent electromagnetic flowmeter consists of two parts: sensors and converters. It works based on Faraday's law of electromagnetic induction and is used to measure the volumetric flow rate of conductive liquids with a conductivity greater than 5 μ S/cm. It is an inductive instrument for measuring the volumetric flow rate of conductive media. In addition to measuring the volumetric flow rate of general conductive liquids, it can also be used to measure the volumetric flow rate of strong corrosive liquids such as strong acids and alkalis, as well as homogeneous liquid-solid two-phase suspensions such as mud, slurry, and pulp. Widely used in industrial sectors such as petroleum, chemical, metallurgical, textile, papermaking, environmental protection, food, as well as municipal management, water conservancy construction, river dredging and other fields for flow measurement. Split type electromagnetic flowmeter is suitable for measuring all corrosive and conductive liquids.

2. Product Features:

All digital processing, strong anti-interference ability, reliable measurement, high accuracy, and a flow measurement range of up to 150:1.
Ultra low EMI switching power supply, suitable for a wide range of power supply voltage changes, with good EMI resistance performance.
Adopting a 16 bit embedded microprocessor, it has fast computing speed, high accuracy, programmable low-frequency rectangular wave excitation, improved stability of flow measurement, and low power consumption.
Using SMD devices and surface mount technology, the circuit has high reliability.
There are no movable parts or flow blocking components inside the pipeline, and there is almost no additional pressure loss during measurement.
On site, the range can be modified online according to the actual needs of the user.
The measurement results are independent of physical parameters such as flow velocity distribution, fluid pressure, temperature, density, viscosity, etc.
High definition backlit LCD display, fully Chinese menu operation, easy to use, simple to operate, easy to learn and understand.
It has digital communication signal outputs such as RS485, RS232, Hart, and Modbus. (Optional)
It has self checking and self judging functions.
Hourly total volume recording function, recording the total flow volume in hours, suitable for time-sharing measurement system (Optional)
There are three integrators inside that can display the forward cumulative amount, reverse cumulative amount, and difference cumulative amount respectively. There is also a non power outage timer inside that can record 16 power outage times. (Optional)
Infrared handheld operator, 115KHZ communication speed, all functions of long-distance non-contact operation converter (Optional).

3. Product Performance:


Nominal diameter: pipeline type DN10~DN1200; Insertion type DN100~DN500

Accuracy level: pipeline type 0.5 grade, 1.0 grade; Insert-type full flow rate >1m/S, ±2.5 grade

Temperature of the measured medium: Ordinary rubber lining: -20 ℃~+60 ℃

High temperature rubber lining: -20 ℃~+90 ℃

PTFE lining: -30 ℃~+100 ℃

High temperature PTFE lining: -20 ℃~+180 ℃

Power supply: AC220V, DC24V, 3.6V Battery

Current output: load resistance 0~10mA: 0~1.5KΩ; 4~20mA: 0~750KΩ

Connection type: Flange connection is used between the flow meter and the piping, the flange connection dimensions should comply with the provisions of GB1198

Split Type Electromagnetic Flow Meter
Split Type Electromagnetic Flow Meter
Split Type Electromagnetic Flow Meter
Split Type Electromagnetic Flow Meter

4. Technical Specifications:

Nominal diameter(mm) Pipeline type: DN4~DN3000
(Special specifications can be customized) Insertion type: DN100~DN3000
Flow direction: Positive, negative, net flow
Range ratio: 150:1
Repetitive error: ± 0.1% of the measured value
Accuracy grade: Pipeline type: 0.5 grade, 1.0 grade
Temperature of the tested medium: Ordinary rubber lining: 20~+60℃
High temperature rubber lining: -20~+90℃
PTFE lining: -30~+100℃
High temperature PTFE lining: -20~+180℃
Rated working pressure: DN6-DN80: ≤1.6MPa
(High pressure customizable) DN100-DN250: ≤1.0MPa

DN300-DN1200: ≤0.6MPa
Flow velocity range: 0.1-15m/s
Conductivity range: The conductivity of the measured fluid ≥5μs/cm
Current output: Load resistance 0~10mA: 0~1.5kΩ
4~20mA: 0~750 kΩ
Digital frequency output: The upper limit of the output frequency can be set within 1-5000Hz with a transistor collector open circuit bidirectional output with photoelectric isolation. When the external power supply is ≤ 35V and conducting, the maximum current at the collector is 250mA.
Power supply: AC220V,DC24V or 3.6V battery
Require the length of the straight pipe Section to be ≥ 5DN upstream and ≥ 2DN downstream
Connection method: The flowmeter and piping are connected by flanges, and the flange connection size should comply with the provisions of GB11988
Explosion proof grade: mdIIBT4
Protection level: IP65, specially customized up to IP68
Environmental temperature: -25~+60℃
Relative temperature: 5%~95%
Total power consumption: less than 20W <20W


5. Selection


① Selection code




Model Description
HQLDE — Rate of flow □ -□ □ □ □ □ □ -□ □ □ □ □
HQLDR — Heat quantity □ -□ □ □ □ □ □ -□ □ □ □ □
Path diameter












10-2200mm
Type S Electromagnetic flowmeter (ordinary integrated type)
B Stainless steel electromagnetic flowmeter
C Insertion type electromagnetic flowmeter
D Clamp type electromagnetic flowmeter
E Fire specific electromagnetic flowmeter
F Small caliber electromagnetic flowmeter
G Sanitary clamp electromagnetic flowmeter
H Battery powered electromagnetic flowmeter
L Split type electromagnetic flowmeter
J High pressure electromagnetic flowmeter
K Wireless remote electromagnetic flowmeter
I Solar powered electromagnetic flowmeter
Installation method F Flange installation
L Threaded installation
K Clamp installation
Electrode material M Stainless steel
T Ti (Titanium)
D Ta (Tantalum)
H Hastelloy alloy
P Pt (Platinum)
N Ni (Nickel)
A Tungsten carbide (wear-resistant)
Output method 0 No output
1 4-20mA/1-5KHz
2 4-20mA
3 24V 4G Wireless remote transmission
4 Battery powered 4G wireless remote transmission
Lining material X Rubber
F PTFE
P F46 (High temperature)
J PFA (Wear resistant)
T
Ceramics
On site display 0 No on-site display
1 On site display
Communication method 0 No communication
1 RS485
2 RS232
3 Mobdus
4 Hart
Grounding 0 No grounding ring
1 Have grounding ring
2 Have grounding electrode
Upper limit rate of flow (n) Upper limit flow rate (range)
m3/h
Work pressure A 0.6MPa
B 1.0 MPa
C 1.6 MPa
D 2,5 MPa
Measurement accuracy 1 0.2
2 0.5
3 1
4
1.5
5
2
6
2.5
Medium temperature L 0-80℃
H 0-150℃
Power supply method DC 24VDC
AC 220VAC
D Battery-powered
T Solar-powered


② Selection of caliber and flow rate


Nominal diameter (mm) Measurable flow range (m³/h) Effective measurement of flow range (m³/h) Nominal diameter (mm) Measurable flow range (m³/h) Effective measurement of flow range (m³/h)
4 0.0135~0.4522 0.0135~0.4522 250 8.8313~2119 52.9875~1766
6 0.0305~1.0173 0.0305~1.0173 300 12.717~3052 76.302~2543
8 0.0543~1.8086 0.0543~1.8086 350 17.31~4154 103.86~3461
10 0.0142~3.3912 0.0848~2.826 400 22.61~5425 135.65~4521
15 0.0318~7.6302 0.1908~6.3585 450 28.62~6867 171.68~5722
20 0.0566~13.5648 0.3392~11.304 500 35.33~8478 211.95~7065
25 0.0883~21.195 0.5298~17.6625 600 50.87~12208 305.2~10173
32 0.1447~34.7258 0.8682~29.9382 700 69.24~16616 415.4~13847
40 0.2261~54.2592 1.3565~45.216 800 90.44~21703 542.6~18086
50 0.3533~84.78 2.1195~70.65 900 114.46~27468 686.7~22890
65 0.5970~143.28 3.5819~119.39 1000 141.3~33912 847.8~28260
80 0.9044~217.03 5.4259~180.86 1200 203.5~48833 1221~40694
100 1.413 ~339.12 8.478~282.6 1400 277~66467 1662~55389
125 2.2079~529.87 13.2468~441.56 1600 361.8~86814 2171~72345
150 3.1793~763 19.0755~635.85 1800 457.9~109874 2747~91562
200 5.652~1356 33.912~1130.4


Split Type Electromagnetic Flow Meter



 Split Type Electromagnetic Flow Meter Manufactures

Split Type Electromagnetic Flow Meter Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Hongqi Automatic Control (Jiangsu) Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)